Menu:



12 Volt DC Submersible PROACTIVE® Pumps For Rent or Sale

Proactive Pumps Low Flow Controller

All pumps come on a reel, with an adjustable rate flow controller, and are decontaminated and tested.

Proactive Pump on a reel
PROACTIVE®_Pumps_Brochure.pdf
File Size: 4751 kb
File Type: pdf
Download File

ajax_proactive_pumps_pricelist.xls
File Size: 565 kb
File Type: xls
Download File


12 Volt DC Submersible PROACTIVE® Pumps for Sale
Click here to view more Proactive Pumps!

Which pump is right for you?
Do you need to know how deep a Proactive pump can go?
Check out the flow chart below
to find the right Proactive pump.


A few words from Proactive:

Dependable - Lightweight- Easy to use 12 volt Groundwater pumps.

Building on over 20 years in business, Proactive Environmental Products™ understands your needs for reliable, accurate, and efficient groundwater pumps. Proactive™ anticipates the changing regulations in the groundwater sampling industry; therefore, continually improving our products based on our customers changing needs. This is the reason why we are the world's premier manufacturer of 12 volt groundwater pumps and accessories with the reputation of simplifying groundwater sampling.

By means of innovation and quality control with every product we manufacture, rest assured when using a Proactive™ pump on your next groundwater sampling event, not only will you cut your sampling time in the field and increase your sampling accuracy, you will find it to truly be a more enjoyable experience.

This is our promise to you!

Low Flow Sampling Made Easy!
1. What is low-flow sampling?
In low-flow sampling a well is purged at a very low rate to minimize drawdown and avoid disturbance in the well, rather than purging a well at a high rate and removing 3-5 volumes of the casing.

2. What are the advantages of low-flow sampling?
Low-flow sampling has a number of important advantages, but they all boil down to better samples at a lower cost. Low-Flow Sampling minimizes drawdown, turbidity and purge volume. Proactive's™ dedicated pumps will not disturb well water.

Here's Why:
Less well disturbance leads to lower sample turbidity, which in turn reduces the variability in the sampling results. Purge volume reduced up to 95%; can reduce purge time/labor in most cases. Reduces problems related to excessive drawdown and pumped volumes. Dedicated equipment for low-flow sampling saves even more field time and eliminates contamination from other wells and equipment handling.

Did You Know...
Traditional Sampling or High-flow pumping increases drawdown, turbidity and purge volume. Bailer movement surges and mixes well, thus, increases turbidity.

3. What equipment do I need to low-flow sample?
  • A sampling device capable of consistently providing low flow rates without agitating the water in the well or altering sample quality.
  • A flow cell to determine completion of purging.
  • A water level measurement device to measure drawdown.
  • With any of Proactive™ pumps the field technician can now low flow sample in an easy and cost effective way!

Portable sampling devices can be used for low-flow sampling, but their use can require more time and extra procedures. First, lowering a portable device into the well mixes the water column between the upper, more stagnant zone, and the screened zone, adding significantly to the time required to complete purging. Second, portable equipment requires cleaning, handling and setup steps; dedicated systems do not.

How do I Low-Flow Sample?
1. What purge flow rate?
Determine a purge flow rate which will minimize drawdown, commonly less than 1 liter/min.

2. How long to purge?
Passing the purge flow through a flow cell measures key water quality parameters, allowing observation of the point when the readings become stable. This commonly occurs within 10-20 minutes, but depends on the well. Sample collection can begin at this point.

3. How much will it cost?
Dedicated PVC pumps from Proactive™ normally reduce costs enough to pay for itself in usually around the first round of sampling! Yes, you read that right, usually within the first round of sampling! Proactive™ manufacturers over 10 pumps all with specific depth capabilities. For example we design pumps that can sample from 25 feet all the way down to 200 feet! A small addition cost is the purchase or rental of a Flow cell.

4. How will low-flow sampling affect regulatory approval of my existing sampling program?
State and federal acceptance of low-flow sampling has been very good, Proactive™ has currently hundreds of sites using our pumps for low-flow sampling . Most of the time, local agencies require only a simple letter for switching over to low-flow sampling. For situations where questions or complexities arise, call Proactive™ for assistance.